Boiler and Pressure Vessel Inspection (260-RICR-30-10-2)

260-RICR-30-10-2 PROPOSED RULE

Title 260 Department of Labor and Training
Chapter 30 Workforce Regulation and Safety
Subchapter 10 Occupational Safety
Part 2 Boiler and Pressure Vessel Inspection (260-RICR-30-10-2)
Type of Filing Amendment
Regulation Status Proposed
Filing Notice Date 10/29/2025
Public Comment Dates 10/29/2025 to 11/29/2025

Regulation Authority:

RIGL 28-25-5 and 28-25-9

Purpose and Reason:

The Department of Labor and Training is amending 260-RICR-30-10-2 to modernize and clarify the boiler and pressure vessel inspection program and incorporate current national safety standards by reference. Substantive updates include revising incorporated materials to the ASME CSD-1:2024, Boiler & Pressure Vessel Code (BPVC) (Edition 2025) and National Board Inspection Code (NBIC) (2025) editions; updating the definition of “Administrator” to clarify that duties assigned by statute may be performed by the Chief Boiler and Pressure Vessel Inspector when expressly delegated by the Director of Labor and Training, while preserving flexibility should the Administrator position be separately filled in the future; reorganizing and alphabetizing the definitions section; revising “certificate of competency” to recognize National Board and other-state credentials as qualifying pathways; to allow the Chief Inspector to require applicants participate in an interview, training session, or other professional dialogue as part of the qualification assessment; and adding definitions for “Commission” and “Commission Card,” reflecting that Rhode Island issues a Commission (evidenced by a Commission Card) to authorized inspectors. The regulation is further updated to mirror current Department practice of commissioning inspectors based on National Board credentials or equivalent foreign US state commissions (while retaining, as allowed by statute, the option of an Administrator approved examination); to require submission of inspection reports within five (5) business days; to require insurers to notify the Chief Inspector within five (5) business days when coverage is written, cancelled, not renewed, or suspended for unsafe conditions (replacing the former 30-day timeline); to remove owner-user inspection agency provisions that are duplicative or no longer necessary; to update procedures and signage for condemned boilers and pressure vessels; to consolidate or eliminate provisions already covered by the adopted national codes; and to update installation requirements, including a carbon monoxide detector in or immediately adjacent to the boiler room for new, reinstalled, and second-hand installations. The rule also clarifies the code application hierarchy so that applicable provisions of the adopted codes govern first and, only when no applicable provision exists, the Chief Inspector may specify requirements using professional judgment grounded in training, experience, and knowledge of the adopted codes and industry practice. No fee increases are proposed.

0

Comment(s) Received*

The agency is not accepting online public comments for this filing.To submit a comment, please contact the agency directly at the addresses listed on the Notice of Proposed Rulemaking.

* This count refers to the total comment submissions received on this document, as of 11:59 PM yesterday.
Note: Agencies review all submissions; however, some agencies may choose to withhold certain submissions such as those containing private or sensitive information, profane or threatening language, or duplicate/near duplicate examples of a mass-mail campaign. This can result in discrepancies between this count and the actual number of comments displayed on this page. For specific information about a comment you submitted, please contact the agency directly.